Whatsapp
8617849334101
Call Us
+86 19562767091
E-mail
zhonghe.bm@outlook.com

Inorganic Pre-Coated Board

Short Description:

Inorganic Pre-Coated Board, also known as Medical Clean Board, uses 100% non-asbestos calcium silicate board as its base material. It is radiation-free and contains no harmful substances such as formaldehyde. The surface undergoes a special coating and UV light curing treatment, which not only enhances the board’s aesthetic appeal but also improves its durability and anti-pollution capabilities. It features excellent fire resistance, moisture resistance, and corrosion resistance, fully meeting modern green and environmental protection requirements.


  • Brand: Zhonghe
  • Place of origin: Henan, China
  • Design Style: Modern
  • After-sale Service: Online Technical Support
  • Packing: Safe Packing
  • Product Detail

    User Guide

    Product Tags

    Product Introduction

    Inorganic Pre-Coated Board, also known as Medical Clean Board, uses 100% non-asbestos calcium silicate board as its base material. It is radiation-free and contains no harmful substances such as formaldehyde. The surface undergoes a special coating and UV light curing treatment, which not only enhances the board’s aesthetic appeal but also improves its durability and anti-pollution capabilities. It features excellent fire resistance, moisture resistance, and corrosion resistance, fully meeting modern green and environmental protection requirements.

    Product Specifications

    Type Length (mm) Width (mm) Thickness (mm)
    Standard 2440 1220 5, 6, 8, 10, 12
    Custom 2440 ~ 3050 1220 5, 6, 8, 10, 12

    Application Scope

    Inorganic Pre-Coated Board is primarily used in environments with high fireproof, moisture-proof, and hygiene requirements:

    • Healthcare: Hospital clean rooms, operating rooms, ICU wards, corridors, and hallways
    • Laboratories: Research labs and testing facilities
    • Food Processing: Food factories and clean production workshops
    • Education: Schools and educational facilities
    • Commercial: Shopping malls, hotels
    • Transportation: Railway stations and public transit hubs

    Product Advantages

    • Class A Fireproof: Excellent fire resistance for critical safety applications
    • Medical-Grade Hygiene: Smooth, non-porous surface inhibits bacterial growth
    • 100% Non-Asbestos: Safe and healthy, free from harmful substances
    • Formaldehyde-Free: Zero formaldehyde emission, meeting strict indoor air quality standards
    • Radiation-Free: Safe for use in sensitive medical and residential environments
    • Anti-Pollution: UV-cured surface resists stains and contaminants
    • Corrosion Resistant: Withstands exposure to chemical cleaning agents
    • Moisture-Proof: Excellent performance in high-humidity environments
    • Durable Finish: UV curing ensures long-lasting color and surface integrity
    • Eco-Friendly: Fully compliant with green building material standards









  • Previous:
  • Next:

  • Storage

    1. Store panels flat in a dry, level indoor area. Stack panels according to specifications on wooden pallets, with a maximum stack height of 1.5 meters.
    2. When panels of different sizes are stored together, place smaller panels on top of larger panels.
    3. For temporary outdoor storage, cover completely with waterproof tarpaulin to protect from rain and direct sunlight exposure.
    Correct Storage
    Correct
    Incorrect Storage
    Incorrect
    Incorrect Storage
    Incorrect

    Handling

    1. Panels must be carried by at least two people, holding the panel flat or vertically. Grip the long edges firmly with arms apart, walk steadily, and handle gently.
    2. Protect the corners and edges from impact. Do not drag panels across surfaces, as this may damage the panel surface.
    3. If temporarily leaning panels against a wall, do not tilt excessively to prevent panels from slipping and causing damage.
    Correct Handling
    Correct
    Correct Handling
    Correct
    Incorrect Handling
    Incorrect
    Incorrect Handling
    Incorrect

    Cutting & Processing

    1. Always use proper protective equipment when cutting. Fiber cement boards are hard and dense — do not use ordinary woodworking saws. Use appropriate cutting equipment and blades, ensuring the panel is supported flat and secured before cutting from the front side.
    2. Use a hole saw for circular openings. For square openings, drill a small hole at each of the four corners with an electric drill first, then cut along the four sides to avoid stress cracking.
    3. For special installation areas such as door and window openings, use multiple square panels to form the required shape rather than cutting the shape directly from a single full board.

    Cleaning & Maintenance

    1. Remove the protective film within 7 days after installation. Use a soft cloth with clean water or a neutral detergent to wipe and clean the surface.
    2. For stubborn stains such as marker pens or ballpoint pen marks, use alcohol or neutral cleaner on a clean cloth for wiping. Never use strong acids, strong alkalis, or corrosive cleaning agents on the panel surface.

    Shipping & Packaging

    1. Products are packaged on pallets, suitable for long-distance transportation.
    2. Small-batch orders can be arranged for LTL (Less Than Truckload) freight shipping.
    3. Large-batch orders can be arranged for dedicated truckload logistics transportation.
    Shipping & Packaging
    Shipping & Packaging
    Write your message here and send it to us